How HMI (Human Machine Interface) is Revolutionizing Human-Machine Interaction in the Digital Era
Reflecting on Achievements And Setting Goals: A Recap of The Company's Annual Conference
The Evolution of HMI (Human Machine Interface) in the Age of Industry 4.0
Leverage HMI (Human Machine Interface) Technology To Enhance User Experience
Understanding HMI (Human Machine Interface) Systems and Their Role in Manufacturing
The Importance of HMI (Human Machine Interface) in Industrial Automation
Understanding the Importance of Solid Shaft Encoders in Industrial Applications
The Advantages of Using Solid Shaft Encoders for Precision Measurement and Control Systems
Choosing the Right Magnetic Rotary Encoder: Factors to Consider
H7BX-A
OMRON
Availability: | |
---|---|
• Highly visible display with backlit transmissive LCD.
• Selectable display color (red/green) enables checking output status at a distance.
• Easy operation with a key for each digit.
• Perform all basic settings with a DIP switch.
• Provides a total and preset counter, batch counter, dual counter, twin counter, and tachometer (See note.).
• Equipped with a Replacement Time Notification Function to be notified in advance by predicting the service life.
• Equipped with a Memory Backup and H7AN Compatibility Function to facilitate problem-free conversion from H7AN.
• Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and 2- wire DC sensors.
• Complies with UL, CSA, and CE marking.
• Degree of protection: IP54 equivalent (front section only).
Note: The functions that can be selected depend on the model.
Function | 1 Stage Preset Counter, Total Preset Counter | |
---|---|---|
Preset stages | 1 step | |
Rated supply voltage | 100 to 240 VAC 50/60 Hz | |
Operating voltage range | 85 to 110% of rated power supply voltage | |
Power consumption | at 100 to 240 VAC: 9.6 VA max. | |
External power supply | 12 VDC (±10%) 100 mA | |
Counter | Count range | -99999 to 999999 |
Max. counting speed | 30 Hz/5 kHz (switching) (ON/OFF ratio 1:1) | |
Minimum input signal width | 30 Hz: 16.7 ms 5 kHz: 0.1 ms | |
Input mode | Increment (UP), decrement (DOWN), increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs)), UP/DOWN D (command input), UP/DOWN E (individual inputs), UP/DOWN E (quadrature inputs)) | |
Output modes | N, F, C, R, K-1, P, Q, A, K-2, D, L | |
One-shot output time | 0.01 to 99.99 s | |
Reset system | External (Minimum input signal width: 1 ms/20 ms selectable, manual and automatic reset (internal according to C, R, P and Q mode operation) | |
Input | Input signal | CP1, CP2, Reset 1, Reset 2, Key protect |
Input method | No-voltage (NPN)/Voltage input (PNP) selectable | |
No-voltage input (No-contact input) | Short-circuit (ON) impedance: 1 kΩ max. (Leakage current (0 Ω): Approx. 12 mA) Residual voltage: 3 V max. Open circuit impedance: 100 kΩ min. | |
No-voltage input (Contact input) | Use a contact which can adequately switch 5 mA at 10 V. | |
Voltage input | Hight level: 4.5 to 30 VDC Low level: 0 to 2 VDC (Input resistance Approx. 4.7 kΩ) | |
Control output | Contact output | SPST-NO 3 A at 250 VAC/30 VDC, resistive load (cos phi=1) Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value) |
Solid-state output | NPN 30 VDC max., 100 mA max. Residual voltage 1.5 V max.DCCapacity value: Approx. 1 V Leakage current 0.1 mA max. | |
Display | Display method | 7-segment backlit negative transmissive LCD |
Digits | 6 digit | |
Character height | Count value: 13.5 mm (Red or green programmable) Set value: 9 mm (green) | |
Prescaling function | 0.001 to 99.999 | |
Decimal point adjustment | Rightmost 3 digits | |
Key protection | Key protect input | |
Memory backup methods | Method: Non-volatile memory, Number of rewite: 100,000 operations min., Store data: 10 years min. | |
Ambient temperature (Operating) | -10 to 55 ℃ (with no icing) | |
Ambient temperature (Storage) | -25 to 65 ℃ (with no icing) | |
Ambient humidity (Operating) | 25 to 85 % (with no condensation) | |
Insulation resistance | Between current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) Between non-continuous contacts: 100 MΩ min. (at 500 VDC) | |
Dielectric withstand voltage | Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between operating power circuit and input circuit: 2000 VAC 50/60 Hz 1 min Between control output, and power supply/input circuit: 2000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min | |
Impulse withstand voltage | Between power terminals: 6 kV Between current carrying terminals and exposed non-current carrying metal parts: 6 kV | |
Noise immunity | Between power terminals: ±1.5 kV Between input terminals: ±600 V square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) | |
Static immunity | Mulfunction: 8 kV, Destruction: 15 kV | |
Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min | |
Shock resistance | Destruction: 294 m/s2, 3 times each in 3 axes 6 directions Malfunction: 98 m/s2, 3 times each in 3 axes 6 directions | |
Life expectancy | Mechanical life 10 million operations min. Electrical life 100,000 operations min. (3 A at 250 VAC resistive load) | |
Degree of protection | Case front: IP54 | |
External connection method | Screw terminal | |
Case color | Black (Munsell N1.5) | |
Accessories | Mounting Bracket, Terminal Cover | |
Weight | Approx. 250 g |
• Highly visible display with backlit transmissive LCD.
• Selectable display color (red/green) enables checking output status at a distance.
• Easy operation with a key for each digit.
• Perform all basic settings with a DIP switch.
• Provides a total and preset counter, batch counter, dual counter, twin counter, and tachometer (See note.).
• Equipped with a Replacement Time Notification Function to be notified in advance by predicting the service life.
• Equipped with a Memory Backup and H7AN Compatibility Function to facilitate problem-free conversion from H7AN.
• Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and 2- wire DC sensors.
• Complies with UL, CSA, and CE marking.
• Degree of protection: IP54 equivalent (front section only).
Note: The functions that can be selected depend on the model.
Function | 1 Stage Preset Counter, Total Preset Counter | |
---|---|---|
Preset stages | 1 step | |
Rated supply voltage | 100 to 240 VAC 50/60 Hz | |
Operating voltage range | 85 to 110% of rated power supply voltage | |
Power consumption | at 100 to 240 VAC: 9.6 VA max. | |
External power supply | 12 VDC (±10%) 100 mA | |
Counter | Count range | -99999 to 999999 |
Max. counting speed | 30 Hz/5 kHz (switching) (ON/OFF ratio 1:1) | |
Minimum input signal width | 30 Hz: 16.7 ms 5 kHz: 0.1 ms | |
Input mode | Increment (UP), decrement (DOWN), increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs)), UP/DOWN D (command input), UP/DOWN E (individual inputs), UP/DOWN E (quadrature inputs)) | |
Output modes | N, F, C, R, K-1, P, Q, A, K-2, D, L | |
One-shot output time | 0.01 to 99.99 s | |
Reset system | External (Minimum input signal width: 1 ms/20 ms selectable, manual and automatic reset (internal according to C, R, P and Q mode operation) | |
Input | Input signal | CP1, CP2, Reset 1, Reset 2, Key protect |
Input method | No-voltage (NPN)/Voltage input (PNP) selectable | |
No-voltage input (No-contact input) | Short-circuit (ON) impedance: 1 kΩ max. (Leakage current (0 Ω): Approx. 12 mA) Residual voltage: 3 V max. Open circuit impedance: 100 kΩ min. | |
No-voltage input (Contact input) | Use a contact which can adequately switch 5 mA at 10 V. | |
Voltage input | Hight level: 4.5 to 30 VDC Low level: 0 to 2 VDC (Input resistance Approx. 4.7 kΩ) | |
Control output | Contact output | SPST-NO 3 A at 250 VAC/30 VDC, resistive load (cos phi=1) Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value) |
Solid-state output | NPN 30 VDC max., 100 mA max. Residual voltage 1.5 V max.DCCapacity value: Approx. 1 V Leakage current 0.1 mA max. | |
Display | Display method | 7-segment backlit negative transmissive LCD |
Digits | 6 digit | |
Character height | Count value: 13.5 mm (Red or green programmable) Set value: 9 mm (green) | |
Prescaling function | 0.001 to 99.999 | |
Decimal point adjustment | Rightmost 3 digits | |
Key protection | Key protect input | |
Memory backup methods | Method: Non-volatile memory, Number of rewite: 100,000 operations min., Store data: 10 years min. | |
Ambient temperature (Operating) | -10 to 55 ℃ (with no icing) | |
Ambient temperature (Storage) | -25 to 65 ℃ (with no icing) | |
Ambient humidity (Operating) | 25 to 85 % (with no condensation) | |
Insulation resistance | Between current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) Between non-continuous contacts: 100 MΩ min. (at 500 VDC) | |
Dielectric withstand voltage | Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between operating power circuit and input circuit: 2000 VAC 50/60 Hz 1 min Between control output, and power supply/input circuit: 2000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min | |
Impulse withstand voltage | Between power terminals: 6 kV Between current carrying terminals and exposed non-current carrying metal parts: 6 kV | |
Noise immunity | Between power terminals: ±1.5 kV Between input terminals: ±600 V square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) | |
Static immunity | Mulfunction: 8 kV, Destruction: 15 kV | |
Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min | |
Shock resistance | Destruction: 294 m/s2, 3 times each in 3 axes 6 directions Malfunction: 98 m/s2, 3 times each in 3 axes 6 directions | |
Life expectancy | Mechanical life 10 million operations min. Electrical life 100,000 operations min. (3 A at 250 VAC resistive load) | |
Degree of protection | Case front: IP54 | |
External connection method | Screw terminal | |
Case color | Black (Munsell N1.5) | |
Accessories | Mounting Bracket, Terminal Cover | |
Weight | Approx. 250 g |