You are here: Home » Programmable Logic Controller (PLC) » PR Programmable Logic Controller » Mini PLC Small Relay PR6 Series Programmable Relay XLogic Model with Non-expandable PR-6DC-DA-R

Products Center

Contact Us

Tel:  +86-577-62791815
Fax: +86-577-62791825
Skype: benjaminying
E-mail:sale@yingselectric.com
Add: NO.126 LIUYANG ROAD, ZHAOYANG INDUSTY ZONE, LIUSHI TOWN, YUEQING CITY, ZHEJIANG, 325604 CHINA

loading

Share to:

Mini PLC Small Relay PR6 Series Programmable Relay XLogic Model with Non-expandable PR-6DC-DA-R

PR-6 Series(Smart Relay) is the entry level model of xLogic Micro PLC family, able to process up to 64 function blocks in a single program, also is the perfect maintenance product, and yet can adequately control a new process from the start.PR-6 Series is capable of replacing many of the discrete components(such as multiple timers, relays, contactors and counters etc) used in conventional systems, opening up a whole new range of possibilities for economical simple control solutions. PR-6 Series exclude expansion feature , NO keypad panel , NO PWM output & High Speed pulse counting capabilities, merely incorporating digital,analog IO, clock with calendar, counters , timers, and available in 120/240VAC or 12V/24VDC versions,Easy to configure with drag-and-drop function blocks using FREE xLogicSoft software.

  • PR-6DC-DA-R

  • RIEVTECH

  • 1

  • ZHEJIANG

  • Automation controller

  • 4 DI+2 relay

  • DC 12-24V

  • 35mm-DIN rail or screw for installation

  • PLC

  • CE

  • 10A

  • Relay output

  • 4 HZ

  • Contact or 3-wire PNP

Availability:


PR-6 Series CPU

Model

Expansion

Supply volt

Inputs

Outputs

High-speed count

PWM

HMI

RTC

G . W(G)

PR-6AC-R      

NO

AC 110~240V

4 DI

2 relays(10A)

NO

NO

NO

YES

180

PR-6DC-DA-R

NO

DC12V-24V

4 DI(I1-I4)
/4(0...10V)

2 relays(10A)

NO

NO

NO

YES

180


GENERAL SPECIFICATIONS

Timers : 64
Counters : 64
Function Blocks: 64
Operation  temp. : -20℃-55℃
Storage:-40℃-70℃
Protection: IP20
RTC accuracy : MAX ±2S/day
RTC time interval : 64
RTC Backup at 25 °C : 20 days
Program and settings Backup :10 years
Data Power-off retentivity : No
Cycle time: typ. 0.6ms to 8.0ms
Dimensions: 48*90*64 (Unit, mm)
Certificate: CE, C-UL, RoSH, REACH
Installation:35mm- DIN rail or screw for installation
Expansion capacity: No
Password protection :4-digit number password protection or disable program upload function
Communication interface : TTL interface , 1 Program/RS232 port
Communication protocol : Modbus RTU/ASCII

Technical Index

Power supply:

Nominal voltage

DC 12-24V

Operating limits

DC 10.8-28.8V

Immunity from micro power cuts

Typ.5 ms

Max. Startup current

Max. 0.25A

Max. absorbed power

1.1 W (10.8V dc) ; 1.2W (28.8V dc)

Protection against polarity inversions

Yes

Input parameters:

Input No

4 ( I1-I4 )

Digital input

4 ( I1-I4 )

Analogue input

4 ( I1-I4)(0..10V DC)

Inputs used as digital inputs( I1-I4 )

Input voltage

DC0-28.8V

Input signal0

< 5V DC;<0.1mA

Input signal1

>8 V DC;>0.3mA

Input current

0.4mA @ 10.8V dc
0.5mA @ 12.0 V dc
1.2mA @ 24 V dc
1.5mA @ 28.8 V dc

Response time

0 to 1 :Typ. 1.5 ms ;1 to 0 :Typ. 1.5 ms

Maximum counting frequency

Typ.:4 HZ

Sensor type

Contact or 3-wire PNP

Input type

Resistive

Isolation between power supply and inputs

None

Isolation between inputs

None

Inputs used as analog inputs( I1-I4 )

Measurement range

DC 0---10V

Input impedance

Min, 24KΩ ; Max. 72KΩ

Input voltage

28.8 V DC max

Resolution

9bit ,0.015V

Accuracy at 25 °C

± (Max.0.03)V

Accuracy at 55 °C

± (Max.0.06)V

Isolation between analog channel and power supply

None

Cable length

10 m max. shielded and twisted

Output parameters:

Output No.

2 (Q1-Q2)

Output type

Relay output

Max. Allowable Power Force

CE: 10A,250V AC/DC30V
UL/CUL:10A,250V AC; 5A, DC28V

Electrical durability Expectancy

105 Operations at Rated Resistive Load

Mechanical life

107 Operations at No Load condition

Response time

Operate Time : 15 mSec. Max.
Release Time : 10 mSec. Max.

Built-in protections

Against short-circuits: None
Against overvoltages and overloads: None

Switch frequency:

Mechanism

10Hz

Resistor/light load

2Hz

Sensitive load

0.5Hz

Other parameters:

Weight

Approx.180g



Installation Dimensions  

1645598518(1)

Wiring Diagram

Input(Digital&Analog 0..10V) & Ouptput(Relay) :

1645599570(1)1645599581(1)

undefined
Previous: 
Next: 
If you have any enquiry about quotation or cooperation,please feel free to email us at sale@yingselectric.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
Contact Us

Quick navigation

Leave a Message
Contact Us

Sensor

Rotary Encoder

Product categories

Contact us

  0086-577-62791815

 0086-577-62791825

  benjaminying


  sale@yingselectric.com

 
Copyright © 2016YUEQING YUMO ELECTRIC CO.,LTD All rights reserved.  Sitemap  Xml                                                                                                                       Designed by tqsh.net