How HMI (Human Machine Interface) is Revolutionizing Human-Machine Interaction in the Digital Era
Reflecting on Achievements And Setting Goals: A Recap of The Company's Annual Conference
The Evolution of HMI (Human Machine Interface) in the Age of Industry 4.0
Leverage HMI (Human Machine Interface) Technology To Enhance User Experience
Understanding HMI (Human Machine Interface) Systems and Their Role in Manufacturing
The Importance of HMI (Human Machine Interface) in Industrial Automation
Understanding the Importance of Solid Shaft Encoders in Industrial Applications
The Advantages of Using Solid Shaft Encoders for Precision Measurement and Control Systems
Choosing the Right Magnetic Rotary Encoder: Factors to Consider
APB-22MRD
YUMO
YM0005551
Availability: | |
---|---|
APB Series PLC,
APB-22MRD without LCD,APB-22MRDL with LCD
Features:
Item | APB-12MRD(L) | APB-12MTD(L) | APB-12MGD(L) | APB-22MRA(L) | APB-24MRDL | ||
APB-22MRD(L) | APB-22MTD(L) | APB-22MGD(L) | APB-12MRA(L) | ||||
Surge Immunity | 2kv(common mode), 1kv(differential mode), Level 3 (IEC61000-4-5) | ||||||
Electrostatic Discharge (outer casing) | ±8kv(air discharge)/±6kv(contact discharge), Level 3 (IEC61000-4-5) | ||||||
Ambient Temperature | -10℃~+55℃ | ||||||
Storage Temperature | -40℃~+70℃ | ||||||
Ambient Humidity | 5%~95%RH | ||||||
Degree of Protection | IP20(Non-waterproof) | ||||||
Installation | Fixing with M3 screws or Standard DIN rail mounting | ||||||
Dimensions (mm) | 71*99*58.5(12 points);126*99*58.5(22 points);126*99*58.5(24 points) | ||||||
Programming Language | FBD | ||||||
Points | 12 points/22 points/24 points/can support 7 I/O extension modules | ||||||
Memory Capacity | 320 FBDs | ||||||
Filtering Duration of Input Signal | It can be set to improve the stability of signal | ||||||
Real-time Clock | 160h,can place a Li-ion battery if it is necessary | ||||||
Password Protection | Multiple passwords protection | ||||||
High-speed Operation | At most 4 high-speed inputs 10KHz, and 2 high-speed outputs 10KHz | ||||||
Analog Operation | At most 12 voltage 0-10V and 2 current 4-20mA analog inputs, and 2 analog outputs 0/4-20mA | ||||||
Power Failure Protection | Yes | ||||||
Simulate Monitoring | Yes | ||||||
Communication Interface | TTL interface; besides, communication module supports 2 RS485 and 1 RS232 interfaces | ||||||
Baud Rate | 9600bps | ||||||
Communication Protocol | MODBUS RTU |
Power Supply | |||||||||
Rated Voltage | DC12-24V | DC12-24V | DC12-24V | AC110-220V | DC12-24V | ||||
Permissible Range | DC11-28V | DC11-28V | DC11-28V | AC85V-265V | DC11-28V | ||||
Power Consumption | 3.5w | -- | -- | -- | -- | ||||
Digital Input | |||||||||
Input Type | NPN/PNP | NPN/PNP | NPN/PNP | NPN/PNP | NPN/PNP | ||||
Input Signal 0 | DC0-5V | DC0-5V | DC0-5V | AC0-70V | DC0-5V | ||||
Input Signal 1 | DC8.5-28V | DC8.5-28V | DC8.5-28V | AC85-265V | DC8.5-28V | ||||
Isolation | Non-isolation | Non-isolation | Non-isolation | Photoelectric isolation | Non-isolation | ||||
Isolated Group | -- | -- | -- | 14 | -- | ||||
Isolated Voltage | -- | -- | -- | 2500/5000Vr.m.s | -- | ||||
Digital Output | |||||||||
Output Type | Relay | Transistor(NPN) | Transistor(PNP) | Relay | Relay | ||||
Rated Voltage | 24VDC/220VAC | 24VDC | 24VDC | 24VDC/220VAC | 24VDC/220VAC | ||||
Isolation Method | Relay isolation | - | - | Relay isolation | Relay isolation | ||||
Analog Input | |||||||||
Input Type | (DC0-10V)/8 inputs | (DC0-10V)/8 inputs | (DC0-10V)/8 inputs | -- | (4-20mA)/2 inputs | ||||
(DC0-10V)/12 inputs | (DC0-10V)/12 inputs | (DC0-10V)/12 inputs | (DC0-10V)/12 inputs | ||||||
Analog Output | |||||||||
Output Type | -- | -- | -- | -- | 4-20mA/2inputs | ||||
A/D Conversion | -- | -- | -- | -- | 12 bits | ||||
Isolation | Non-isolation | Non-isolation | Non-isolation | Non-isolation | Non-isolation | ||||
High-speed Operation | |||||||||
4 inputs /10KHz | 4 inputs /10KHz | 4 inputs /10KHz | -- | 4 inputs /10KHz | |||||
Input Type | Support single-phase counter and two-phase counter | Support single-phase counter and two-phase counter | Support single-phase counter and two-phase counter | -- | Support single-phase counter and two-phase counter | ||||
2 outputs / 10KHZ | 2 outputs /10KHZ | ||||||||
Output Type | -- | Supports multiple outputs: PTO pulse output, PWM pulse width modulation and acceleration/ deceleration single-phase pulse | Supports multiple outputs: PTO pulse output, PWM pulse width modulation and acceleration/ deceleration single-phase pulse | -- | -- |
Note: The economical type is supplied without LCD panel, and the basic type is supplied with LCD panel. | |||
APB-12MRD(L) | DC12V-24V | 8 points digital input (can be used as analog inputs); I4-I7 can be high-speed ports | 4 points relay output |
APB-12MTD(L) | DC12V-24V | 8 points digital input (can be used as analog inputs); I4-I7 can be high-speed ports | 4 points NPN transistor output |
Q2、Q3 can be high-speed output ports | |||
APB-12MGD(L) | DC12V-24V | 8 points digital input (can be used as analog inputs); I4-I7 can be high-speed ports | 4 points PNP transistor output |
Q2、Q3 can be high-speed output ports | |||
APB-22MRA(L) | AC100V-240V | 14 points input | 8 points relay output |
APB-22MRD(L) | DC12V-24V | 14 points digital input (the first 12 points can be analog inputs); I4-I7 can be high-speed ports | 8 points relay output |
APB-22MTD(L) | DC12V-24V | 14 points digital input (the first 12 points can be analog inputs); I4-I7 can be high-speed ports | 8 points NPN transistor output |
Q2、Q3 can be high-speed output ports | |||
APB-22MGD(L) | DC12V-24V | 14 points digital input (the first 12 points can be analog inputs); I4-I7 can be high-speed ports | 8 points PNP transistor output |
Q2、Q3 can be high-speed output ports | |||
APB-24MRDL | DC12V-24V | 2points for current input, and 14points for digital input (the first 12 points can be 0~10V analog inputs); I4-I7 can be high-speed ports | 6 points relay output + 2 analog outputs |
APB-22ERA | AC100V-240V | 14 points digital input | 8 points relay output |
APB-22ERD | DC12V-24V | 14 points digital input | 8 points relay output |
APB-22ETD | DC12V-24V | 14 points digital input | 8 point NPN transistor output |
APB-22EGD | DC12V-24V | 14 points digital input | 8 point NPN transistor output |
APB-SMS | supports I/O control and SMS alarm, as well as receives and sends short message in another mode | |||||||
APB-EXPMC | applied in the long-distance signal transmission interface and constitutes a nerwork with 485 bus | |||||||
APB-EXNET | use cable network and TCP/IP protocol to link the remote netw |
APB Series PLC,
APB-22MRD without LCD,APB-22MRDL with LCD
Features:
Item | APB-12MRD(L) | APB-12MTD(L) | APB-12MGD(L) | APB-22MRA(L) | APB-24MRDL | ||
APB-22MRD(L) | APB-22MTD(L) | APB-22MGD(L) | APB-12MRA(L) | ||||
Surge Immunity | 2kv(common mode), 1kv(differential mode), Level 3 (IEC61000-4-5) | ||||||
Electrostatic Discharge (outer casing) | ±8kv(air discharge)/±6kv(contact discharge), Level 3 (IEC61000-4-5) | ||||||
Ambient Temperature | -10℃~+55℃ | ||||||
Storage Temperature | -40℃~+70℃ | ||||||
Ambient Humidity | 5%~95%RH | ||||||
Degree of Protection | IP20(Non-waterproof) | ||||||
Installation | Fixing with M3 screws or Standard DIN rail mounting | ||||||
Dimensions (mm) | 71*99*58.5(12 points);126*99*58.5(22 points);126*99*58.5(24 points) | ||||||
Programming Language | FBD | ||||||
Points | 12 points/22 points/24 points/can support 7 I/O extension modules | ||||||
Memory Capacity | 320 FBDs | ||||||
Filtering Duration of Input Signal | It can be set to improve the stability of signal | ||||||
Real-time Clock | 160h,can place a Li-ion battery if it is necessary | ||||||
Password Protection | Multiple passwords protection | ||||||
High-speed Operation | At most 4 high-speed inputs 10KHz, and 2 high-speed outputs 10KHz | ||||||
Analog Operation | At most 12 voltage 0-10V and 2 current 4-20mA analog inputs, and 2 analog outputs 0/4-20mA | ||||||
Power Failure Protection | Yes | ||||||
Simulate Monitoring | Yes | ||||||
Communication Interface | TTL interface; besides, communication module supports 2 RS485 and 1 RS232 interfaces | ||||||
Baud Rate | 9600bps | ||||||
Communication Protocol | MODBUS RTU |
Power Supply | |||||||||
Rated Voltage | DC12-24V | DC12-24V | DC12-24V | AC110-220V | DC12-24V | ||||
Permissible Range | DC11-28V | DC11-28V | DC11-28V | AC85V-265V | DC11-28V | ||||
Power Consumption | 3.5w | -- | -- | -- | -- | ||||
Digital Input | |||||||||
Input Type | NPN/PNP | NPN/PNP | NPN/PNP | NPN/PNP | NPN/PNP | ||||
Input Signal 0 | DC0-5V | DC0-5V | DC0-5V | AC0-70V | DC0-5V | ||||
Input Signal 1 | DC8.5-28V | DC8.5-28V | DC8.5-28V | AC85-265V | DC8.5-28V | ||||
Isolation | Non-isolation | Non-isolation | Non-isolation | Photoelectric isolation | Non-isolation | ||||
Isolated Group | -- | -- | -- | 14 | -- | ||||
Isolated Voltage | -- | -- | -- | 2500/5000Vr.m.s | -- | ||||
Digital Output | |||||||||
Output Type | Relay | Transistor(NPN) | Transistor(PNP) | Relay | Relay | ||||
Rated Voltage | 24VDC/220VAC | 24VDC | 24VDC | 24VDC/220VAC | 24VDC/220VAC | ||||
Isolation Method | Relay isolation | - | - | Relay isolation | Relay isolation | ||||
Analog Input | |||||||||
Input Type | (DC0-10V)/8 inputs | (DC0-10V)/8 inputs | (DC0-10V)/8 inputs | -- | (4-20mA)/2 inputs | ||||
(DC0-10V)/12 inputs | (DC0-10V)/12 inputs | (DC0-10V)/12 inputs | (DC0-10V)/12 inputs | ||||||
Analog Output | |||||||||
Output Type | -- | -- | -- | -- | 4-20mA/2inputs | ||||
A/D Conversion | -- | -- | -- | -- | 12 bits | ||||
Isolation | Non-isolation | Non-isolation | Non-isolation | Non-isolation | Non-isolation | ||||
High-speed Operation | |||||||||
4 inputs /10KHz | 4 inputs /10KHz | 4 inputs /10KHz | -- | 4 inputs /10KHz | |||||
Input Type | Support single-phase counter and two-phase counter | Support single-phase counter and two-phase counter | Support single-phase counter and two-phase counter | -- | Support single-phase counter and two-phase counter | ||||
2 outputs / 10KHZ | 2 outputs /10KHZ | ||||||||
Output Type | -- | Supports multiple outputs: PTO pulse output, PWM pulse width modulation and acceleration/ deceleration single-phase pulse | Supports multiple outputs: PTO pulse output, PWM pulse width modulation and acceleration/ deceleration single-phase pulse | -- | -- |
Note: The economical type is supplied without LCD panel, and the basic type is supplied with LCD panel. | |||
APB-12MRD(L) | DC12V-24V | 8 points digital input (can be used as analog inputs); I4-I7 can be high-speed ports | 4 points relay output |
APB-12MTD(L) | DC12V-24V | 8 points digital input (can be used as analog inputs); I4-I7 can be high-speed ports | 4 points NPN transistor output |
Q2、Q3 can be high-speed output ports | |||
APB-12MGD(L) | DC12V-24V | 8 points digital input (can be used as analog inputs); I4-I7 can be high-speed ports | 4 points PNP transistor output |
Q2、Q3 can be high-speed output ports | |||
APB-22MRA(L) | AC100V-240V | 14 points input | 8 points relay output |
APB-22MRD(L) | DC12V-24V | 14 points digital input (the first 12 points can be analog inputs); I4-I7 can be high-speed ports | 8 points relay output |
APB-22MTD(L) | DC12V-24V | 14 points digital input (the first 12 points can be analog inputs); I4-I7 can be high-speed ports | 8 points NPN transistor output |
Q2、Q3 can be high-speed output ports | |||
APB-22MGD(L) | DC12V-24V | 14 points digital input (the first 12 points can be analog inputs); I4-I7 can be high-speed ports | 8 points PNP transistor output |
Q2、Q3 can be high-speed output ports | |||
APB-24MRDL | DC12V-24V | 2points for current input, and 14points for digital input (the first 12 points can be 0~10V analog inputs); I4-I7 can be high-speed ports | 6 points relay output + 2 analog outputs |
APB-22ERA | AC100V-240V | 14 points digital input | 8 points relay output |
APB-22ERD | DC12V-24V | 14 points digital input | 8 points relay output |
APB-22ETD | DC12V-24V | 14 points digital input | 8 point NPN transistor output |
APB-22EGD | DC12V-24V | 14 points digital input | 8 point NPN transistor output |
APB-SMS | supports I/O control and SMS alarm, as well as receives and sends short message in another mode | |||||||
APB-EXPMC | applied in the long-distance signal transmission interface and constitutes a nerwork with 485 bus | |||||||
APB-EXNET | use cable network and TCP/IP protocol to link the remote netw |