YUMO inverters can be used for temporary events in the desert
How Can Implementing Safety Light Curtains Improve Workplace Safety?
Looking Ahead: Future Innovations in Rotary Encoder Technology
Choosing the Right Encoder: Rotary Encoder vs. Potentiometer
Celebrating the YUMO Company's 16th Anniversary: A Milestone of Excellence and Success
TZN4S-14R
Autonics
Availability: | |
---|---|
Display method : 4-digit 7-segment LED
Control method : ON/OFF control, P, PI, PD, PIDF, PIDS control
Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), R(PR), S(PR), N(NN), W(TT)
RTD: DPt100Ω, JPt100Ω
Analog: 1-5VDC , 0-10VDC , DC4-20mA
Sampling cycle : 500ms
Control output : Relay(250VAC~ 3A)
Power supply : 100-240VAC~ 50/60Hz
Display method | 4-digit 7-segment LED |
---|---|
Control method | ON/OFF control, P, PI, PD, PIDF, PIDS control |
Input specification | Thermocouple: K(CA), J(IC), E(CR), T(CC), R(PR), S(PR), N(NN), W(TT) RTD: DPt100?, JPt100? Analog: 1-5VDC , 0-10VDC , DC4-20mA |
Sampling cycle | 500ms |
Control output | Relay(250VAC~ 3A) |
Option output | Event 1 |
Power supply | 100-240VAC~ 50/60Hz |
Approval | |
Display accuracy | F.S ± 0.3% or 3?, select the higher one |
Alarm output hysteresis | 1 to 100? (0.1 to 100.0?) variable |
Proportional band | 0.0 to 100.0% |
Integral time | 0 to 3,600 sec |
Derivative time | 0 to 3,600 sec |
Control period | 1 to 120 sec |
LBA setting | 1 to 999 sec |
Ramp setting | Ramp Up, Ramp Down: 1 to 99 min each |
Environment_Ambient temperature | -10 to 50℃, storage: -20 to 60℃ |
Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
Weight | Approx. 226g(approx. 164g) |
Display method : 4-digit 7-segment LED
Control method : ON/OFF control, P, PI, PD, PIDF, PIDS control
Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), R(PR), S(PR), N(NN), W(TT)
RTD: DPt100Ω, JPt100Ω
Analog: 1-5VDC , 0-10VDC , DC4-20mA
Sampling cycle : 500ms
Control output : Relay(250VAC~ 3A)
Power supply : 100-240VAC~ 50/60Hz
Display method | 4-digit 7-segment LED |
---|---|
Control method | ON/OFF control, P, PI, PD, PIDF, PIDS control |
Input specification | Thermocouple: K(CA), J(IC), E(CR), T(CC), R(PR), S(PR), N(NN), W(TT) RTD: DPt100?, JPt100? Analog: 1-5VDC , 0-10VDC , DC4-20mA |
Sampling cycle | 500ms |
Control output | Relay(250VAC~ 3A) |
Option output | Event 1 |
Power supply | 100-240VAC~ 50/60Hz |
Approval | |
Display accuracy | F.S ± 0.3% or 3?, select the higher one |
Alarm output hysteresis | 1 to 100? (0.1 to 100.0?) variable |
Proportional band | 0.0 to 100.0% |
Integral time | 0 to 3,600 sec |
Derivative time | 0 to 3,600 sec |
Control period | 1 to 120 sec |
LBA setting | 1 to 999 sec |
Ramp setting | Ramp Up, Ramp Down: 1 to 99 min each |
Environment_Ambient temperature | -10 to 50℃, storage: -20 to 60℃ |
Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
Weight | Approx. 226g(approx. 164g) |