YUMO inverters can be used for temporary events in the desert
How Can Implementing Safety Light Curtains Improve Workplace Safety?
Looking Ahead: Future Innovations in Rotary Encoder Technology
Choosing the Right Encoder: Rotary Encoder vs. Potentiometer
Celebrating the YUMO Company's 16th Anniversary: A Milestone of Excellence and Success
TCN4S-24R
Autonics
| Availability: | |
|---|---|
Display method : 4-digit 7-segment LED
Control method : ON/OFF, P, PI, PD, PID
Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC)
RTD: DPt100Ω, Cu50Ω
Sampling cycle : 100ms
Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
Power supply : 100-240VAC~ 50/60Hz
![]()
| Display method | 4-digit 7-segment LED |
|---|---|
| Control method | ON/OFF control, P, PI, PD, PID control |
| Input specification | Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100?, Cu50℃ |
| Sampling cycle | 100ms |
| Control output | Relay(250VAC~ 3A) or SSR drive(12VDC |
| Option output | Alarm 1/2 |
| Power supply | 100-240VAC~ 50/60Hz |
| Approval | |
| Display accuracy_RTD | •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit •Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit |
| Display accuracy_Thermocouple | •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit •Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit |
| Hysteresis(adjustable sensitivity) | 1 to 100℃/℉(0.1 to 50.0℃/℉) variable |
| Proportional band | 0.1 to 999.9?/? |
| Integral time | 0 to 9999 sec |
| Derivative time | 0 to 9999 sec |
| Control period | 0.5 to 120.0 sec |
| Manual reset | 0.0 to 100.0% |
| Environment_Ambient temperature | -10 to 50?, storage: -20 to 60℃ |
| Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
| Insulation type | Double insulation or reinforced insulation(mark: |
| Weight | Approx. 147g(approx. 100g) |
Display method : 4-digit 7-segment LED
Control method : ON/OFF, P, PI, PD, PID
Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC)
RTD: DPt100Ω, Cu50Ω
Sampling cycle : 100ms
Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
Power supply : 100-240VAC~ 50/60Hz
![]()
| Display method | 4-digit 7-segment LED |
|---|---|
| Control method | ON/OFF control, P, PI, PD, PID control |
| Input specification | Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100?, Cu50℃ |
| Sampling cycle | 100ms |
| Control output | Relay(250VAC~ 3A) or SSR drive(12VDC |
| Option output | Alarm 1/2 |
| Power supply | 100-240VAC~ 50/60Hz |
| Approval | |
| Display accuracy_RTD | •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit •Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit |
| Display accuracy_Thermocouple | •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit •Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit |
| Hysteresis(adjustable sensitivity) | 1 to 100℃/℉(0.1 to 50.0℃/℉) variable |
| Proportional band | 0.1 to 999.9?/? |
| Integral time | 0 to 9999 sec |
| Derivative time | 0 to 9999 sec |
| Control period | 0.5 to 120.0 sec |
| Manual reset | 0.0 to 100.0% |
| Environment_Ambient temperature | -10 to 50?, storage: -20 to 60℃ |
| Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
| Insulation type | Double insulation or reinforced insulation(mark: |
| Weight | Approx. 147g(approx. 100g) |