YUMO inverters can be used for temporary events in the desert
How Can Implementing Safety Light Curtains Improve Workplace Safety?
Looking Ahead: Future Innovations in Rotary Encoder Technology
Choosing the Right Encoder: Rotary Encoder vs. Potentiometer
Celebrating the YUMO Company's 16th Anniversary: A Milestone of Excellence and Success
TCN4L-24R
Autonics
Availability: | |
---|---|
Display method : 4-digit 7-segment LED
Control method : ON/OFF, P, PI, PD, PID
Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC)
RTD: DPt100Ω, Cu50Ω
Sampling cycle : 100ms
Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
Power supply : 100-240VAC~ 50/60Hz
Display method | 4-digit 7-segment LED |
---|---|
Control method | ON/OFF control, P, PI, PD, PID control |
Input specification | Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100?, Cu50℃ |
Sampling cycle | 100ms |
Control output | Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF] |
Option output | Alarm 1/2 |
Power supply | 100-240VAC~ 50/60Hz |
Approval | |
Display accuracy_RTD | •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit •Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit |
Display accuracy_Thermocouple | •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit •Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit |
Hysteresis(adjustable sensitivity) | 1 to 100℃/℉(0.1 to 50.0℃/℉) variable |
Proportional band | 0.1 to 999.9?/? |
Integral time | 0 to 9999 sec |
Derivative time | 0 to 9999 sec |
Control period | 0.5 to 120.0 sec |
Manual reset | 0.0 to 100.0% |
Environment_Ambient temperature | -10 to 50℃, storage: -20 to 60℃ |
Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
Insulation type | Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: AC power 2kV, AC/DC Power 1kV) |
Weight | Approx. 275g(approx. 179g) |
Display method : 4-digit 7-segment LED
Control method : ON/OFF, P, PI, PD, PID
Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC)
RTD: DPt100Ω, Cu50Ω
Sampling cycle : 100ms
Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
Power supply : 100-240VAC~ 50/60Hz
Display method | 4-digit 7-segment LED |
---|---|
Control method | ON/OFF control, P, PI, PD, PID control |
Input specification | Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100?, Cu50℃ |
Sampling cycle | 100ms |
Control output | Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF] |
Option output | Alarm 1/2 |
Power supply | 100-240VAC~ 50/60Hz |
Approval | |
Display accuracy_RTD | •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit •Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit |
Display accuracy_Thermocouple | •At room temperature(23ºC ± 5ºC):(PV ± 0.5% or ±1ºC, select the higher one) ± 1-digit •Out of room temperature range:(PV± 0.5% or ±2ºC, select the higher one)± 1-digit |
Hysteresis(adjustable sensitivity) | 1 to 100℃/℉(0.1 to 50.0℃/℉) variable |
Proportional band | 0.1 to 999.9?/? |
Integral time | 0 to 9999 sec |
Derivative time | 0 to 9999 sec |
Control period | 0.5 to 120.0 sec |
Manual reset | 0.0 to 100.0% |
Environment_Ambient temperature | -10 to 50℃, storage: -20 to 60℃ |
Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
Insulation type | Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: AC power 2kV, AC/DC Power 1kV) |
Weight | Approx. 275g(approx. 179g) |