content is empty!
WTB26P-24161120A00
SICK
2
Original
10-30VDC
24.6 mm x 82.5 mm x 53.3 mm
Photoelectric proximity sensor
CE
Push-pull: PNP/NPN
Availability: | |
---|---|
100 % new and original sick Sensors and Accessories SICK WTB26P-24161120A00 Compact photoelectric sensors W26
FEATURES
Functional principle | Photoelectric proximity sensor |
Functional principle detail | Background suppression |
Sensing range | |
Sensing range min. | 30 mm |
Sensing range max. | 1,600 mm |
Adjustable switching threshold for background suppression | 180 mm ... 1,600 mm |
Reference object | Object with 90% remission (based on standard white, DIN 5033) |
Minimum distance between set sensing range and background (black 6% / white 90%) | 40 mm, at a distance of 600 mm |
Recommended sensing range for the best performance | 200 mm ... 600 mm |
Emitted beam | |
Light source | PinPoint LED |
Type of light | Visible red light |
Shape of light spot | Point-shaped |
Light spot size (distance) | Ø 7 mm (700 mm) |
Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle) | < |
Key LED figuresNormative referenceEN 62471:2008-09 | IEC 62471:2006, modifiedLED risk group markingFree groupWave length635 nmAverage service life100,000 h at Ta = +25 °C | |
AdjustmentTeach-Turn adjustmentBluePilot: For setting the sensing rangeIO-LinkFor configuring the sensor parameters and Smart Task functions |
Indication | |
LED blue | BluePilot: sensing range indicator |
LED green | Operating indicator Static on: power on Flashing: IO-Link mode |
LED yellow | Status of received light beam Static on: object present Static off: object not present |
MTTFD | 629 years |
DCavg | 0 % |
TM (mission time) | 20 years (EN ISO 13849) Rate of use: 60 % |
Communication interface
IO-Link | ✔ , V1.1 |
Data transmission rate | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure | Bit 0 = switching signal QL1 |
Bit 1 = switching signal QL2 | |
Bit 2 ... 15 = empty | |
VendorID | 26 |
DeviceID HEX | 0x800178 |
DeviceID DEC | 8388984 |
Compatible master port type | A |
SIO mode support | Yes |
Supply voltage UB | 10 V DC ... 30 V DC 1) |
Ripple | ≤ 5 Vpp |
Usage category | DC-12 (According to EN 60947-5-2) DC-13 (According to EN 60947-5-2) |
Current consumption | ≤ 30 mA, without load. At UB = 24 V |
Protection class | III |
Digital output | |
Number | 2 (Complementary) |
Type | Push-pull: PNP/NPN |
Signal voltage PNP HIGH/LOW | Approx. UB-2.5 V / 0 V |
Signal voltage NPN HIGH/LOW | Approx. UB / < 2.5 V |
Output current Imax. | ≤ 100 mA |
Circuit protection outputs | Reverse polarity protected |
Overcurrent and short-circuit protected | |
Response time | ≤ 500 µs 2) |
Repeatability (response time) | 150 µs |
Switching frequency | 1,000 Hz 3) |
Pin/Wire assignmentFunction of pin 4/black (BK)Digital output, light switching, object present → output QL1 HIGH; IO-Link communication CFunction of pin 4/black (BK) – detailThe pin 4 function of the sensor can be configured, Additional possible settings via IO-LinkFunction of pin 2/white (WH)Digital output, dark switching, object present → output ǬL1 LOWFunction of pin 2/white (WH) – detailThe pin 2 function of the sensor can be configured, Additional possible settings via IO-Link |
1) Limit values.
2) Signal transit time with resistive load in switching mode.
3) With light/dark ratio 1:1.
Housing | Rectangular |
Dimensions (W x H x D) | 24.6 mm x 82.5 mm x 53.3 mm |
Connection | Male connector M12, 4-pin |
MaterialHousingPlastic, VISTAL®Front screenPlastic, PMMAMale connectorPlastic, VISTAL® | |
Weight | Approx. 80 g |
Maximum tightening torque of the fixing screws | 1.3 Nm |
Enclosure rating | IP66 (EN 60529) IP67 (EN 60529) IP69 (EN 60529) 1) |
Ambient operating temperature | –40 °C ... +60 °C |
Ambient temperature, storage | –40 °C ... +75 °C |
Shock resistance | 50 g, 11 ms (25 positive and 25 negative shocks per axis, for X, Y, Z axes, 150 shocks in total (EN60068-2-27)) 50 g, 6 ms (5,000 positive and 5,000 negative shocks per axis, for X, Y, Z axes, 30,000 shocks in total (EN60068-2-27)) |
Vibration resistance | 10 Hz ... 2,000 Hz (Amplitude 0.5 mm / 10 g, 20 sweeps per axis, for X, Y, Z axes, 1 octave/min, (EN60068-2-6)) |
Air humidity | 35 % ... 95 %, Relative humidity (no condensation) |
Electromagnetic compatibility (EMC) | EN 60947-5-2 |
Resistance to cleaning agent | ECOLAB |
UL File No. | NRKH.E181493 & NRKH7.E181493 |
1) Replaces IP69K with ISO 20653: 2013-03.
100 % new and original sick Sensors and Accessories SICK WTB26P-24161120A00 Compact photoelectric sensors W26
FEATURES
Functional principle | Photoelectric proximity sensor |
Functional principle detail | Background suppression |
Sensing range | |
Sensing range min. | 30 mm |
Sensing range max. | 1,600 mm |
Adjustable switching threshold for background suppression | 180 mm ... 1,600 mm |
Reference object | Object with 90% remission (based on standard white, DIN 5033) |
Minimum distance between set sensing range and background (black 6% / white 90%) | 40 mm, at a distance of 600 mm |
Recommended sensing range for the best performance | 200 mm ... 600 mm |
Emitted beam | |
Light source | PinPoint LED |
Type of light | Visible red light |
Shape of light spot | Point-shaped |
Light spot size (distance) | Ø 7 mm (700 mm) |
Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle) | < |
Key LED figuresNormative referenceEN 62471:2008-09 | IEC 62471:2006, modifiedLED risk group markingFree groupWave length635 nmAverage service life100,000 h at Ta = +25 °C | |
AdjustmentTeach-Turn adjustmentBluePilot: For setting the sensing rangeIO-LinkFor configuring the sensor parameters and Smart Task functions |
Indication | |
LED blue | BluePilot: sensing range indicator |
LED green | Operating indicator Static on: power on Flashing: IO-Link mode |
LED yellow | Status of received light beam Static on: object present Static off: object not present |
MTTFD | 629 years |
DCavg | 0 % |
TM (mission time) | 20 years (EN ISO 13849) Rate of use: 60 % |
Communication interface
IO-Link | ✔ , V1.1 |
Data transmission rate | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure | Bit 0 = switching signal QL1 |
Bit 1 = switching signal QL2 | |
Bit 2 ... 15 = empty | |
VendorID | 26 |
DeviceID HEX | 0x800178 |
DeviceID DEC | 8388984 |
Compatible master port type | A |
SIO mode support | Yes |
Supply voltage UB | 10 V DC ... 30 V DC 1) |
Ripple | ≤ 5 Vpp |
Usage category | DC-12 (According to EN 60947-5-2) DC-13 (According to EN 60947-5-2) |
Current consumption | ≤ 30 mA, without load. At UB = 24 V |
Protection class | III |
Digital output | |
Number | 2 (Complementary) |
Type | Push-pull: PNP/NPN |
Signal voltage PNP HIGH/LOW | Approx. UB-2.5 V / 0 V |
Signal voltage NPN HIGH/LOW | Approx. UB / < 2.5 V |
Output current Imax. | ≤ 100 mA |
Circuit protection outputs | Reverse polarity protected |
Overcurrent and short-circuit protected | |
Response time | ≤ 500 µs 2) |
Repeatability (response time) | 150 µs |
Switching frequency | 1,000 Hz 3) |
Pin/Wire assignmentFunction of pin 4/black (BK)Digital output, light switching, object present → output QL1 HIGH; IO-Link communication CFunction of pin 4/black (BK) – detailThe pin 4 function of the sensor can be configured, Additional possible settings via IO-LinkFunction of pin 2/white (WH)Digital output, dark switching, object present → output ǬL1 LOWFunction of pin 2/white (WH) – detailThe pin 2 function of the sensor can be configured, Additional possible settings via IO-Link |
1) Limit values.
2) Signal transit time with resistive load in switching mode.
3) With light/dark ratio 1:1.
Housing | Rectangular |
Dimensions (W x H x D) | 24.6 mm x 82.5 mm x 53.3 mm |
Connection | Male connector M12, 4-pin |
MaterialHousingPlastic, VISTAL®Front screenPlastic, PMMAMale connectorPlastic, VISTAL® | |
Weight | Approx. 80 g |
Maximum tightening torque of the fixing screws | 1.3 Nm |
Enclosure rating | IP66 (EN 60529) IP67 (EN 60529) IP69 (EN 60529) 1) |
Ambient operating temperature | –40 °C ... +60 °C |
Ambient temperature, storage | –40 °C ... +75 °C |
Shock resistance | 50 g, 11 ms (25 positive and 25 negative shocks per axis, for X, Y, Z axes, 150 shocks in total (EN60068-2-27)) 50 g, 6 ms (5,000 positive and 5,000 negative shocks per axis, for X, Y, Z axes, 30,000 shocks in total (EN60068-2-27)) |
Vibration resistance | 10 Hz ... 2,000 Hz (Amplitude 0.5 mm / 10 g, 20 sweeps per axis, for X, Y, Z axes, 1 octave/min, (EN60068-2-6)) |
Air humidity | 35 % ... 95 %, Relative humidity (no condensation) |
Electromagnetic compatibility (EMC) | EN 60947-5-2 |
Resistance to cleaning agent | ECOLAB |
UL File No. | NRKH.E181493 & NRKH7.E181493 |
1) Replaces IP69K with ISO 20653: 2013-03.