Integrating PLCs for Seamless Operation in Industrial Machinery
The Importance of PLC Programming in Manufacturing Processes
How HMI (Human Machine Interface) is Revolutionizing Human-Machine Interaction in the Digital Era
Reflecting on Achievements And Setting Goals: A Recap of The Company's Annual Conference
The Evolution of HMI (Human Machine Interface) in the Age of Industry 4.0
ADK-1020170013SA
YUMO
1
China
5V/8-30V
Availability: | |
---|---|
Analog usage instructions
The encoder uses a line shorting method to set the start position of the current output.
Example of 4-20mA setting method
1. Connect the red wire of the encoder to the positive terminal of the power supply and the black wire to the negative terminal of the power supply.
2. Rotate the encoder to the position where the 4mA current value needs to be set;
3、Short connect the orange wire to the positive terminal of the power supply for more than 1 second and then release it, the orange wire will be suspended or grounded.
4、Rotate the encoder clockwise to the position where 20mA current value needs to be set;
5, the yellow wire and power supply positive short connection, time greater than 1 second after the release, the yellow wire hanging or ground.
Until this current setting is completed, rotate the encoder between these two positions, the encoder output current changes continuously between 4-20mA.
Note: It is not possible to set 4mA and 20mA in the same position, if you have any questions, please contact us.
Specification parameter
Maximum permissible mechanical speed | 5000r/min |
working temperature | -25℃~+85℃ |
Storage temperature | -25℃~+90℃ |
protection class | IP54 |
CONNECTION TABLE
Signal | 8-30VDC | GND(0V) | 0-10V | 0V Setting Line | 10V Setting Line | Shield |
Color | red | black | gray | orange | yellow | thick black |
Analog usage instructions
The encoder uses a line shorting method to set the start position of the current output.
Example of 4-20mA setting method
1. Connect the red wire of the encoder to the positive terminal of the power supply and the black wire to the negative terminal of the power supply.
2. Rotate the encoder to the position where the 4mA current value needs to be set;
3、Short connect the orange wire to the positive terminal of the power supply for more than 1 second and then release it, the orange wire will be suspended or grounded.
4、Rotate the encoder clockwise to the position where 20mA current value needs to be set;
5, the yellow wire and power supply positive short connection, time greater than 1 second after the release, the yellow wire hanging or ground.
Until this current setting is completed, rotate the encoder between these two positions, the encoder output current changes continuously between 4-20mA.
Note: It is not possible to set 4mA and 20mA in the same position, if you have any questions, please contact us.
Specification parameter
Maximum permissible mechanical speed | 5000r/min |
working temperature | -25℃~+85℃ |
Storage temperature | -25℃~+90℃ |
protection class | IP54 |
CONNECTION TABLE
Signal | 8-30VDC | GND(0V) | 0-10V | 0V Setting Line | 10V Setting Line | Shield |
Color | red | black | gray | orange | yellow | thick black |