This model is a DC power supply, rated voltage can be DC12/24V, 12 points DC digital input (can be used as analog input), 8 points transistor output (exuivalent PNP), without LCD.
Exquisite and compact design
Multi-functional, easy operating, convenient, easy learning
Dimensions: (unit:mm)
Take the 10 points module as an example. The 20 points modules share the same width and height, the only one difference exists in the length.
Item | AF-10MR-A2 | AF-10MR-D2 | AF-10MR-E2 | AF-10MT-D2 | AF-10MT-GD2 | AF-10MT-E2 | |
AF-20MR-A2 | AF-20MR-D2 | AF-20MR-E2 | AF-20MT-D2 | AF-20MT-GD2 | AF-20MT-E2 | ||
Surge Immunity | 2kv(common mode), 1kv(differential mode), Level 3 (IEC61000-4-5) | ||||||
Electrostatic Discharge (outer casing) | ±8kv(air discharge)/±6kv(contact discharge), Level 3 (IEC61000-4-5) | ||||||
Ambient Temperature | -10℃~+55℃ | ||||||
Storage Temperature | -40℃~+70℃ | ||||||
Ambient Humidity | 5%~95%RH | ||||||
Degree of Protection | IP20(Non-waterproof) | ||||||
Installation | Fixing with M3 screws or Standard DIN rail mounting | ||||||
Dimensions (mm) | 71.6*90.4*51.3(10 points);126.4*90.4*51.3(20 points) | ||||||
Programming Language | FBD | ||||||
Points | 10 points/20 points | ||||||
Memory Capacity | 127 FBDs | ||||||
Real-time Clock | 160h | ||||||
Password Protection | yes | ||||||
Analog Operation | At most 12 channels with DC 0-10V voltage | ||||||
Simulate Monitoring | Yes | ||||||
Communication Interface | support 2 channel with RS485 and 1 channel with program interfaces | ||||||
Baud Rate | 9600bps/19200bps | ||||||
Communication Protocol | Self-defined protocol/MODBUS RTU protocol | ||||||
Power Supply | |||||||
Rated Voltage | AC100-240V | DC12-24V | AC/DC12-24V | DC12-24V | DC12-24V | DC12-24V | |
Permissible Range | DC85-260V | DC10-28V | AC/DC10-28V | DC10-28V | DC10-28V | DC10-28V | |
Power Consumption | <10w | <7w | <7w | <2w | <2w | <2w | |
Digital Input | |||||||
Input Type | NPN/PNP | NPN/PNP | NPN/PNP | NPN/PNP | NPN/PNP | NPN/PNP | |
Input Signal 0 | AC0-40V | DC0-5V | AC/DC0-5V | DC0-5V | DC0-5V | DC0-5V | |
Input Signal 1 | AC80-240V | DC10-24V | AC/DC10-24V | DC10-24V | DC10-24V | DC10-24V | |
Isolation | Photoelectric isolation | / | / | / | / | / | |
Isolated Group | 6/12 groups | ||||||
Isolated Voltage | 2500/5000Vr.m.s | ||||||
Digital Output | |||||||
Output Type | Relay | Relay | Relay | Transistor(NPN) | Transistor(PNP) | Transistor(NPN) | |
Isolation Method | Relay isolation | Relay isolation | Relay isolation | - | - | - | |
Analog Input | |||||||
Input Type | -- | (DC0-10V)/6 inputs | -- | (DC0-10V)/6 inputs | (4-20mA)/2 inputs | -- | |
(DC0-10V)/12 inputs | (DC0-10V)/12 inputs | (DC0-10V)/12 inputs |
Product Pictures
Model NO.: AF-20MT-GD2
This model is a DC power supply, rated voltage can be DC12/24V, 12 points DC digital input (can be used as analog input), 8 points transistor output (exuivalent PNP), without LCD.
Exquisite and compact design
Multi-functional, easy operating, convenient, easy learning
Dimensions: (unit:mm)
Take the 10 points module as an example. The 20 points modules share the same width and height, the only one difference exists in the length.
Item | AF-10MR-A2 | AF-10MR-D2 | AF-10MR-E2 | AF-10MT-D2 | AF-10MT-GD2 | AF-10MT-E2 | |
AF-20MR-A2 | AF-20MR-D2 | AF-20MR-E2 | AF-20MT-D2 | AF-20MT-GD2 | AF-20MT-E2 | ||
Surge Immunity | 2kv(common mode), 1kv(differential mode), Level 3 (IEC61000-4-5) | ||||||
Electrostatic Discharge (outer casing) | ±8kv(air discharge)/±6kv(contact discharge), Level 3 (IEC61000-4-5) | ||||||
Ambient Temperature | -10℃~+55℃ | ||||||
Storage Temperature | -40℃~+70℃ | ||||||
Ambient Humidity | 5%~95%RH | ||||||
Degree of Protection | IP20(Non-waterproof) | ||||||
Installation | Fixing with M3 screws or Standard DIN rail mounting | ||||||
Dimensions (mm) | 71.6*90.4*51.3(10 points);126.4*90.4*51.3(20 points) | ||||||
Programming Language | FBD | ||||||
Points | 10 points/20 points | ||||||
Memory Capacity | 127 FBDs | ||||||
Real-time Clock | 160h | ||||||
Password Protection | yes | ||||||
Analog Operation | At most 12 channels with DC 0-10V voltage | ||||||
Simulate Monitoring | Yes | ||||||
Communication Interface | support 2 channel with RS485 and 1 channel with program interfaces | ||||||
Baud Rate | 9600bps/19200bps | ||||||
Communication Protocol | Self-defined protocol/MODBUS RTU protocol | ||||||
Power Supply | |||||||
Rated Voltage | AC100-240V | DC12-24V | AC/DC12-24V | DC12-24V | DC12-24V | DC12-24V | |
Permissible Range | DC85-260V | DC10-28V | AC/DC10-28V | DC10-28V | DC10-28V | DC10-28V | |
Power Consumption | <10w | <7w | <7w | <2w | <2w | <2w | |
Digital Input | |||||||
Input Type | NPN/PNP | NPN/PNP | NPN/PNP | NPN/PNP | NPN/PNP | NPN/PNP | |
Input Signal 0 | AC0-40V | DC0-5V | AC/DC0-5V | DC0-5V | DC0-5V | DC0-5V | |
Input Signal 1 | AC80-240V | DC10-24V | AC/DC10-24V | DC10-24V | DC10-24V | DC10-24V | |
Isolation | Photoelectric isolation | / | / | / | / | / | |
Isolated Group | 6/12 groups | ||||||
Isolated Voltage | 2500/5000Vr.m.s | ||||||
Digital Output | |||||||
Output Type | Relay | Relay | Relay | Transistor(NPN) | Transistor(PNP) | Transistor(NPN) | |
Isolation Method | Relay isolation | Relay isolation | Relay isolation | - | - | - | |
Analog Input | |||||||
Input Type | -- | (DC0-10V)/6 inputs | -- | (DC0-10V)/6 inputs | (4-20mA)/2 inputs | -- | |
(DC0-10V)/12 inputs | (DC0-10V)/12 inputs | (DC0-10V)/12 inputs |