NDR-480-24 240W Single Output Industrial DIN RAIL

Product Description

Features

·Universal AC input / Full range

.Built-in active PFC function

.Protections: Short circuit /Overload /Over voltage/ Over temperature

·Cooling by free air convection

. Can be installed on DlN rail TS-35/7.5 or 15"UL 508 (industrial control equipment) approved"BS EN/EN61000-6-2(BS EN/EN50082-2) industrial immunity level

.100% full load burn-in test

3 years warranty


Applications

.industrial control system

.Semi-conductor fabrication equipment

.Factory automation"Electro-mechanical


Description

NDR-240 is one economical slim 240W Din rail power supply series, adapt to be installed on TS-35/7.5or TS-35/15 mounting rails. The body is designed 63mm in width, which allows space saving inside thecabinets. The entire series adopts the full range Ac inputfrom 9OVAC to 264VAC and conforms toBS EN/EN61000-3-2, the norm the European Union regulates for harmonic current.NDR-240 is designed with metal housing that enhances the unit's power dissipation. With working eficiencyup to 90%, the entire series can operate at the ambient temperature between -20'c and 70'c under ailconvection. it is equipped with constant current mode for over-load protection, fitting various inductiveor capacitive applications. The complete protection functions and relevant certificates for industrial controlapparatus (UL508, TUV BS EN/EN62368-1, and etc.) make NDR-240 a very competitive power supplysolution for industrial applications.


SPECIFICATION


MODEL NDR-240-24 NDR-240-48
OUTPUT DC VOLTAGE 24V 48V
RATED CURRENT 10A 5A
CURRENT RANGE 0 ~ 10A 0 ~ 5A
RATED POWER 240W 240W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 24 ~ 28V 48 ~ 55V
VOLTAGE TOLERANCE Note.3 ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0%
SETUP, RISE TIME 1500ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.) 28ms/230VAC 22ms/115VAC at full load
INPUT VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.) 88.5% 90%
AC CURRENT (Typ.) 2.5A/115VAC 1.3A/230VAC
INRUSH CURRENT (Typ.) 20A/115VAC 35A/230VAC
LEAKAGE CURRENT <1mA / 240VAC
PROTECTION OVERLOAD 105 ~ 130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 29 ~ 33V 56 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT WORKING TEMP. -20 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT ± 0.03 (0 ~ 50 )
VIBRATION Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25'C of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 x F & 47 uF parallel capacitor.3. Tolerance : includes set up tolerance, line requlation and load requlation.4. Derating may be needed under low input voltage. Please check the derating curve for more details.5. ihstallaion clearances : 40mm on top, 20mm on the botom, 5mm on the left and right side are recommended when loaded permanently with fiul powerIn case the adjacent device is a heat source, 15mm clearance is recommended.6. The power supply is considered a component which will be instaled into a final equipment. The final equipment must be re-conrmed that it stll meetEMC directives. For guidance on how to perform these ElMC tests, please refer to "EMl testing of component power supplies."(as available on https://www.meanwell.com//Upload/PDF/EMl statement en.pdf )

1.The ambient temperature derating of 3.5'c/1000m with fanless models and of 5*c/1000m with fan models for operating alttude higher than2000m(6500ft).